Reinforced beams using unidirectional CFRP fabric

Because of the insufficient bearing capacity of the original concrete beams, carbon fiber reinforced polymer(CFRP) fabric is used in the strengthening method.The lack of reinforcement area * reinforcement tensile strength design value is less than or equal to the carbon fiber cloth thickness * width * design value of tensile strength of carbon fiber cloth

Reinforced beams using unidirectional CFRP fabric


Problem types

Because of the insufficient bearing capacity of the original concrete beams, carbon fiber reinforced polymer(CFRP) fabric is used in the strengthening method.


The parameters of the carbon fiber sheet at the bottom of the beam:

CFRP grade: Grade I

Modulus of elasticity Ecf = 2.30 * 105 MPa

Design value of tensile strength FF = 2300 MPa

Single layer thickness t CFV = 0.167 mm

Weight: 300g/m2

Do not consider the two force


Reinforced beams using unidirectional CFRP fabric


The reinforcement area is 750mm2 after the load is increased, and the bond size of carbon fiber cloth is converted by the equal strong substitution principle.

Design value of tensile strength of steel bar: 360N/mm2

Design value of tensile strength of carbon fiber cloth: 2300 N/mm2


The lack of reinforcement area * reinforcement tensile strength design value is less than or equal to the carbon fiber cloth thickness * width * design value of tensile strength of carbon fiber cloth

750*360 = 0.167* width *2300

Width = 702.94


The dimension of beam section is 400*900, and the width of structural beam is 400, which can not meet the width of carbon fiber cloth. Considering the double layer carbon fiber cloth, the carbon fiber cloth multilayer paste reduction factor is calculated.

The reduction coefficient of =1.16- (layers of elastic modulus design value * * thickness) /308000 = 0.9

=1.16-(2*230000*0.167)/308000 

 

 

 

 

 

 

 

 

=0.91

=1.16-(2*230000*0.167)/308000 

 

 

 

 

 

 

 

 

=0.91

                                              =1.16-(2*230000*0.167)/308000        

                                              =0.91

Reduction coefficient            =0.9


750*360 = 0.167* width *2300*0.9

Width = 781.05


The width of beam is 400mm, CFRP double-layer area: 2*400=800 = 781.05, meet the strength requirements.


Horse Construction Recommended Products

You can find anything here you are in need of, have a trust trying on these products, you will find the big difference after that.

HM-20 Unidirectional Carbon Fiber Wrap

High strength, unidirectional carbon fiber wrap pre-saturated to form a carbon fiber reinforced polymer (CFRP) wrap used to strengthen structural concrete elements.

See more >

HM-180 Carbon Fiber Primer

Low viscosity, strong penetration carbon fiber primer for reinforced concrete surface to enhace the defect part

See more >

HM-180C3P Carbon Fiber Adhesive

Good impregnation carbon fiber adhesive for applying carbon fiber reinforced polymer(CFRP) wrap for structural strengthening

See more >

Back
Top
Close