Which structure can't be removed in house retrofitting?

The housing structure needs to ensure its overall safety and can not be arbitrarily dismantled and altered. It must undergo strict inspection and appraisal, give detailed consideration to the housing structure, and the final transformation should be carried out under the condition of safety.

can't be removed in house retrofitting


1.The load-bearing walls must not be removed, if the wall is gone, will the gravity balance throughout the house was destroyed, the harm to the whole house is very large, in addition to the walls, some light wall should also note that not all of the light wall can be removed, to see the house the whole architecture. It also plays a role in writing the load-bearing lightweight wall, such as light wall beam under the.


The hollow slab inside the house can be demolished, because these plates only play the role of space separation, beautification and no bearing function. All the demolition and demolition of these walls will not threaten the safety of the houses.


2.Steel bars buried in walls cannot be demolished. If these steel bars are removed, they will affect the bearing capacity of the whole floor and walls, and later there will be a threat of wall collapse.


3.Standing on the balcony on the edge of a wall is not Cagai, because this wall plays an important role in protecting the balcony, the balcony to pull effect on weight, if we put this wall down to the balcony, then it is likely because of weightlessness and falling, which is very dangerous.


4.A lot of people will replace the original doorframe according to their own ideas, but the doorframe is fixed in the concrete. If we force it to demolish, it will destroy the original building structure, and it will be difficult to carry out subsequent door decoration.


5.For some columns and beams in the construction of our housing is not arbitrarily removed, because the beam column is the role of supporting a floor, if we were forcibly removed, and makes losing support to the floor collapsed, very dangerous.


6.Even if some housing structures can be demolished, we cannot ignore the overall safety. In the process of transformation, we need to emphasize the reinforcement of structures to ensure the overall stability.

Horse Construction Recommended Products

You can find anything here you are in need of, have a trust trying on these products, you will find the big difference after that.

HM-1.2T Unidirectional Carbon Fiber Strip

High strength carbon fiber reinforced polymer (CFRP) strip / laminate / plate for structural strengthening and concrete repair

See more >

HM-60 Unidirectional Carbon Fiber Sheet

High strength, unidirectional carbon fiber sheet pre-saturated to form a carbon fiber reinforced polymer (CFRP) sheet used to strengthen structural concrete elements.

See more >

HM-500 Injection Anchoring Adhesive

Two-components modified epoxy resin adhesive, with high quality plastic tube, double cartridge package for anchoring

See more >

Back
Top
Close